español english français italiano deutsch 中文
回到主页 产品解决方案 销售 支持 联系我们 关于我们

 
Tech Tips
  Am I using the right heatsink?
For additional information:

AMERICAS

United States and Canada
2320 Paseo de las Americas,
Suite 201, San Diego, CA 92154
sales@crydom.com

Sales Support: (877) 502 5500
Technical Support: (877) 702 7700
Fax (619) 710 8540

Mexico
Tel: +52 (222) 409 7000
Fax: +52 (222) 409 7810

South America
Tel: +55 (11) 3026 9008
Fax: +55 (11) 3026 9009

EUROPE

United Kingdom
Tel: +44 (0) 1202 606030

Fax: +44 (0) 1202 606035

Germany
Tel: +49 (0) 180 3000 506

Italy
Tel: +39 02 66599260
Fax: +39 02 66599268

France
Tel: 0 810 123 963
Fax: 0 810 057 605

ASIA

China
Tel: +86 (21) 6249 0910
Fax: +86 (21) 6249 0701

Taiwan
Tel: +886 2 8751 6388 x130
Fax: +886 2 2657 8725

India
Tel: +91 (80) 329 02 245
Fax: +91 (80) 412 38 066

OTHER REGIONS

Tel: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035

How to verify the proper Heat Sink

In certain instances, once the heat sink requirements for a SSR in a particular application have been determined and installed, (see the Crydom paper entitled SELECTING A SUITBLE HEATSINK), it may be desirable to verify that the system does indeed provide adequate cooling to ensure reliable SSR operation.

The following is a relatively simple method to check this suitability, and essentially uses some of the calculations from SELECTING A SUITABLE HEAT SINK in a reverse manner. This technique may also be used on existing systems in the field that might have been more or less “empirically” designed, to gain information on their performance and potential reliabilty. This method involves determining the temperature of the internal power devices, (SCR’s or Triac), within the SSR and then comparing that temperature with a “standard” absolute maximum temperature that the SSR power devices must never exceed. The maxium power device temperature is generally considered to be 125°C but for an added safety margin, 115°C should be used. (Of course for the truest indication, the entire system being evaluated should be stable and operating at its maximum rated parameters including load currents, ambient temperatures, and with doors and access panels in their normal o perating positions.)

There are three additional pieces of data needed to perform this evaluation. They are the actual load current switched by the SSR, the specified “Thermal Resistance – Junction to Case” - Rθjc of the SSR, and the measured temperature of the SSR base plate. Ideally, the temperature measurement of the SSR base plate should be taken directly from the bottom center of the SSR. However, since in most installations this is not practical since the SSR is mounted to a heat sink surface, the next best accessible location is on the top surface of the base plate near the mounting screw holes at the junction of the plastic case to the base plate surface. (To compensate for this measurement location, it is a good practice to add 3 to 5 degrees to the actual measurement.)

Using the above data, and an estimated power drop of 1 Watt for every 1 Arms of load current, the total internal dissipation in Watts can be calculated. (e.g. 35 Arms load = 35 Watts of internal dissipation.) Next, multiply the internal dissipation in Watts by the Rθjc value, (in °C/W), to determine the internal temperature rise. This temperature value is added to the measured base plate temperature to arrive at the calculated temperature of the internal power devices. If this value is less than the 115°C “standard maximum with safety margin” value, then the heat sink is adequate.

In some cases, the heat sink information and derate curves provided within the SSR specification sheets may include expected base plate temperatures, but generally do not consider the safety margin values.